CelSafe® CO₂ Incubators

CelSafe® CO₂ Incubators

High Heat Sterilization Cycle

  • Fully automatic 200°C sterilization cycle with a simple touch on the screen.
  • Effectiveness of high heat sterilization cycle is validated through in-house laboratory test.
  • All components and accessories are designed to meet 200°C temperature requirement.
  • Complies with different international guideline requirements for dry heat sterilization such as U.S. and E.U. Pharmacopeias.
  • Everything is STANDARD to avoid running cost on other external accessories and consumables just to perform  sterilization cycle.
  • The entire sterilization cycle period is less than 9 hours.

 

Latest Infrared CO₂ Sensor Technology

  • CARBOCAP® technology for heat durability and long term stability
  • With full temperature and pressure compensation
  • No need to remove CO₂ probe inside the chamber during sterilization cycle, thus, saving time and reducing risk of cross contamination.
  • Water vapor, dust, other chemicals, change in temperature, humidity, other gases and pressure do not affect the performance of the IR sensor.
  • Internal pressure sensor improves accuracy and stability.
  • Sensor head is heated to prevent condensation.

 

Optimized Clean Chamber Design

  • New ribbed design chamber allows installation of shelves without screws or pilasters.
  • Minimize risk of contamination
  • Easy maintenance
  • Quick and easy to clean
  • More chamber space

 

Complete Security System

  • Multiple over-temperature protection system guarantee maximum sample, user and environment protection.
  • All electrical components are UL recognized.
  • Electrical circuit protection is in accordance with UL requirements.
  • PIN code prevents unauthorized access on screen menu and functions.
  • Magnetic Door Lock System
    • Manually locks during normal operation to protect samples
    • Automatically locks during high heat sterilization cycle to protect users
  • Inlet Door Latch function turns off pump, gas supply, and heating functions when the door is opened.

 

CelTouch Screen Control System

  • Big, clear, and easy-to-read parameter display
  • Easy to follow on-screen icon menus
  • Actual Data Graph, Data Logging functions, Event Logs and Alarm Functions are easily seen on the screen.
  • Easy download of data log files using USB Write menu
  • Fully functional even with gloved fingers
  • Multiple language selections: English, German, Spanish, French, Italian

 

Active Humidification System

  • In order to provide optimal environmental conditions for cell growth that requires specific relative humidity, the CelSafe® CO₂ incubator with optional active humidity control allows user to actively control humidity from up to 95%.
  • Water reservoir is located at the back of the chamber. No more water pan.
  • Heats up and maintain water reservoir based on RH control.
  • Water inlet valve is triggered by water level sensor.

IR Sensor Model with Stainless Steel Chamber

Model Description
CLS-170B-8 CelSafe® Incubator, 170 L, IR Sensor, CO₂ Control, High Heat Sterilization, 230 VAC, 50/60 Hz
CLS-170B-9 CelSafe® Incubator, 170 L, IR Sensor, CO₂ Control, High Heat Sterilization, 115 VAC, 50/60 Hz

IR Sensor Model with Stainless Steel Chamber and Active Humidification

Model Description
CLS-170B-8-RH CelSafe® Incubator, 170 L, IR Sensor, CO₂ Control, High Heat Sterilization, Active Humidification, 230 VAC, 50/60 Hz
CLS-170B-9-RH CelSafe® Incubator, 170 L, IR Sensor, CO₂ Control, High Heat Sterilization, Active Humidification, 115 VAC, 50/60 Hz

Suppressed O2 Model with Stainless Steel Chamber

Model Description
CLS-170T-8 CelSafe® Incubator, 170 L, IR Sensor, CO₂ and O₂ Control, High Heat Sterilization, 230 VAC, 50/60 Hz
CLS-170T-9 CelSafe® Incubator, 170 L, IR Sensor, CO₂ and O₂ Control, High Heat Sterilization, 115 VAC, 50/60 Hz

Suppressed O2 Model with Stainless Steel Chamber and Active Humidification

Model Description
CLS-170T-8-RH CelSafe® Incubator, 170 L, IR Sensor, CO₂ and O₂ Control, High Heat Sterilization, Active Humidification,230 VAC, 50/60 Hz
CLS-170T-9-RH CelSafe® Incubator, 170 L, IR Sensor, CO₂ and O₂ Control, High Heat Sterilization, Active Humidification,115 VAC, 50/60 Hz

Options:

  • COA-1002: CO₂ Backup (Tank Switcher), Factory Installed
  • COA-1002-F: CO₂ Backup (Tank Switcher), Field-Installed Kit
  • COA-2033-F: Sealed Inner Door Kit for 170 L (4 Glass Doors with Latches), Field Installed
  • COA-2038: Sealed Inner Door Kit for 170 L (4 Glass Doors with Latches), Factory Installed
  • COA-1007: N₂ Backup (Tank Switcher), Factory Installed
  • COA-1007-F: N₂ Backup (Tank Switcher), Field Installed

 

Accessory:

  • COA-2034-F: Roller Base
  • COA-2035-F: Floor Stand 200 mm (8”) Adjustable Feet
  • COA-2036-F: Floor Stand 700 mm (27.6”)
  • COA-2005-F: 2-Stage Gas Regulator for CO₂/N₂
  • CGA 320: CGA 320 Connector (US Standard)
  • BP-BS341#08-NT4: BP-BS34-#8-NT4 Connector (British Standard)
  • G5/8-RH: G5/8-RH Connector (China Standard)
  • OA-2037-F: Extra Stainless Steel Shelf
  • COA-2010-F: Electronic CO₂ Analyzer (Worldwide), for CO₂ / Temp Measurement (with Temperature Probe)
  • COA-2016-F: Electronic CO₂ Analyzer (Worldwide), for CO₂ / O₂ / Temp Measurement (with Temperature Probe)
  • COA-2017-F: Electronic CO₂ Analyzer (Worldwide), for CO₂ / O₂ / RH / Temp Measurement (with Temperature Probe)
  • COA-2011-F: IQ/OQ Documentation
  • COA-2015-F: Inner Door Shelving Kit